Примеры использования Measuring screen на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
MEASURING SCREEN.
Point on measuring screen.
Settings directly accessible on measuring screen.
Annex 3 Measuring screen.
Measuring screen geometry and measuring grid 38.
Figure A: Measuring screen 1.
Measuring Screen for Class B Headlamp, delete test point B5 and the dimension 250 mm to read.
Annex 4: Measuring screens.
Sub menu“Memory” After selecting the memory function, the status line on the measuring screen is modified.
Annex 3: Measuring screens.
Following a comment by the expert from the European Commission, concerning the table in annex X2,the expert from Germany said that it would be preferable to measure the positions of the specified points on the measuring screen in angular degrees, instead of millimetres.
Annex 4 measuring screen geometry and measuring grid.
For the passing beam, the values prescribed in this Regulation are met at HV(with a tolerance of+ 0.2 lx) andrelated to that aiming at least one point of each area delimited on the measuring screen(at 25 m) by a circle 15 cm in radius around points B 50 L.
Annex 4: Measuring screen geometry and measuring grid.
For the passing beam, the values prescribed in this Regulation are met at HV(with a tolerance of+ 0.2 lx) andrelated to that aiming at one point of each area delimited on the measuring screen(at 25 m) by a circle 15 cm in radius around points B 50 L(or R) 1/(with a tolerance of+ 0.1 lx), 75 R(or L), 50 V, 25 R1, 25 L2, and on segment I;
Annex 3, after the title"MEASURING SCREEN for Class A headlamps" read"Figure A" and after the title"MEASURING SCREEN for Class B headlamps" read"Figure B.
As the proposed amendments were in particular modifying the requirements of the cut-off line and the measuring screen, GRE referred informal document No. GRE-53-4 to the GTB working group in order to study in detail the impact of the proposed modifications.
The cleaning efficiency at the points on the measuring screen which are specified below shall, after every cleaning period, amount to at least 70 per cent for the passing lamp and also 70 per cent for the optional driving lamp; in case of an AFS this provision applies to the photometric system value as defined in Annex 9 to Regulation No. 123 from those lighting units indicated in paragraph 6.1.1. above.
For the passing beam, the values prescribed in this Regulation are met at HV(with a tolerance of+ 170 cd)and related to that aiming at least one point of each area delimited on the measuring screen(at 25 m) by a circle 15 cm in radius around points B 50 L(or R) 1/(with a tolerance of 85 cd), 75 R(or L), 50 V, 25 R, 25 L, and in the entire area of zone IV which is not more than 22.5 cm above line 25 R and 25 L;
The cleaning efficiency at the points on the measuring screen which are specified below shall, after every cleaning period, amount to at least 70 per cent for the headlamp producing the principal passing beam and also 70 per cent for the optional headlamp producing the driving beam; in case of an AFS this provision applies to the photometric system value as defined in Annex 9 to Regulation No. 123 from those lighting units indicated in paragraph 6.1.1. above.
The conditions shall be as described in the relevant Regulation based at the measuring screen centre(H-V) located at the height of the headlamp reference axis and in a vertical plane including headlamp reference axis.
The output signal returns to the active state andthe measured sample value is shown on the measure screen.
Changes the name that corresponds to the sensor on the top of the measure screen.
A measuring scale on the light transmitting screen should be used for measuring sizes of examined objects.
The show is set in turn on two opposite catwalks,each positioned against a background of a multimedia screen measuring over 150 sq.m.
The data is displayed on a screen mounted on the measuring table.
Package data is displayed on a screen mounted on the measuring table.
You can pick two points by measuring a distance on the screen.
C1-90 single-beam oscilloscope universal service is intended for visual observation of the form of electrical signals on the CRT screen and measuring the amplitude and timing parameters.