Примеры использования Burning time на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
Burning time: about 40 min.
Burnt distance and burning time;
Burning time- up to 1 minute.
Everything after that was just a way of burning time.
Burning time for nominal output 4 h.
Used alone or in combination with other materials,it gives a long burning time.
Fuel burning time, to, hour**.
Solid-fuel long-burning steam generators"Wichlacz" KW-GSN 750 kW to 1000 kg of steam per hour increased the burning time on a single fuel load.
T20-80 burning time between 20% to 80% of total mass loss in seconds.
On order of the mines"Vostochnaya" and"Zarechnaya" experts of Rubex Group have developed hydraulic hoses with self-extinguishing properties- burning time and smoldering after a short exposure to the flame does not exceed 30 seconds.
The measurement of the burning time starts at the moment when the foot of the flame passes the first measuring point.
In some burn time trials, individual packages orarticles will be observed to burn in separate, identifiable events; in such cases, the burning times and masses of each separate event should be used.
Using a highperformance LED a burning time of up to 60 hours per set of batteries is possible!
A burning time of the product measured to be less than 35 seconds for 100 kg net explosive mass see 16.6.1.4.8 Notes for scaling time measurements in evaluating thermal flux effects.
Principal is that your body is lighter, burning time of a small amount of sugar at the time, compared with large sums.
The burning time of the fuel boiler depends on the type of fuel, humidity, outdoor temperature and other factors.
Readily flammable solids which, when tested, have a burning time of less than 45 seconds over a measured distance of 100 mm shall be assigned to.
If the sample does not ignite or does not continue burning after the burner has been extinguished, orthe flame goes out before reaching the first measuring point, so that no burning time is measured, note in the test report that the burning rate is 0 mm/min.
Measurement of burning time starts at the moment when the foot of the flame passes the first measuring point.
If the sample does not ignite or does not continue burning after the burner has been extinguished orif the flame extinguishes before the destruction of one of the first marker threads occurred, so that no burning time is measured, the burning rate is considered to be 0 mm/min.
The measurement of the burning time starts at the moment when the leading edge of the flame passes the first measuring point.
In so far as the sample does not ignite or does not continue burning after the burner has been extinguished, orwhen the flame extinguishes before reaching the first measuring point, so that no burning time is measured note in the test report that the burning rate is 0 mm/min.
It provides an even longer burning time thanks to Pacific Energy's top technology for the manufacturing combustion chambers.
Reflective stripes of 400 cm2 on the front and 100 cm2 on the back, the whistle, search electrofire that meets SOLAS Convention SOLAS-74/96 and LSA Code requirements with water-activated battery, 10 years of service life, intensity 0,75Kd,fire burning time at least 8 hours, lifting device to get out of the water, floating safety line, packing bag.
Measurement of burning time is completed when the flame has come to the last measuring point or when the flame is extinguished before reaching that point.
Procedure and limits:ambient temperature 20 °C; air speed in test chamber 1 m/s; burning time of the navigation light before the test 2 h; maximum allowable surface temperature according to Table 6.
Measurement of burning time is completed when the flame has come to the last measuring point or when the flame extinguishes before coming to the last measuring point.
With the exception of metal powders or powders of metal alloys, powdery, granular or pasty substances shall be classified as readily flammable substances of Class 4.1 if they can be easily ignited by brief contact with an ignition source(e.g. a burning match), or if,in the event of ignition, the flame spreads rapidly, the burning time is less than 45 seconds for a measured distance of 100 mm or the rate of burning is greater than 2.2 mm/s.
Measurement of the burning time is completed when the flame reaches the last measuring point or when the flame goes out before reaching this point.
If the true heat of combustion is significantly different, the burning time of 35 sec may be corrected; for example, a true heat of combustion of 8372 J/g burning for(8372/12500)× 35 s 23.4 s would produce the same flux level.