Примери за използване на Insulated boots на Английски и техните преводи на Български
{-}
-
Colloquial
-
Official
-
Medicine
-
Ecclesiastic
-
Ecclesiastic
-
Computer
Insulated boots outside and flags.
Preventive test of insulated boots.
Next: Insulated boots outside and flags.
Next: Preventive test of insulated boots.
Previous: Insulated boots outside and flags.
Previous: Preventive test of insulated boots.
Insulated boots outside and flags Navigation.
More reliably discriminate gloves(insulated boots) leakage….
Insulated boots gloves current tester Parameters.
The inside and outside of the insulated boots(gloves) are at the same height.
Protect the test workers,it is the ideal special equipment for the insulating gloves(insulated boots).
When the four, wearing insulated boots, pants into the boots should be simple.
When using, wear insulated gloves and insulated boots as needed.
Test methods and cycles insulated boots and gloves and other safety equipment used for.
(11) Wear a safety helmet,insulated gloves and insulated boots when handling.
HZGZ gloves(insulated boots) Pressure unit is based gloves(insulated boots) the test procedures, design and production.
Remove the sponge when the inside and outside of the insulated boots(gloves) are filled with water.
Descrption HZGZ gloves(insulated boots) Pressure unit is based gloves(insulated boots) the test procedures, design and production.
Insulated boots insulated gloves are not allowed to break down during the withstand voltage test and the leakage current must not exceed the required value.
More reliably discriminate gloves(insulated boots) leakage current, insulation aging, power frequency withstand voltage and other parameters.
Insulated boots and gloves pressure test, a period of six months, the breakdown is not allowed during the test, and insulated boots leakage current is less than the limit value.
Kv Electrical Glove Inspection dielectric insulated gloves testing Product Description insulated boots gloves current tester Insulated boots and gloves are essential power system operation and maintenance of safety equipment, DL408 electricity safety regulations and electrical insulation shoes….
Insulated boots and gloves are essential power system operation and maintenance of safety equipment, DL408 electricity safety regulations and electrical insulation shoes GB12011-2000 General technical requirements and test methods specified period insulated boots and gloves and other safety equipment used in.
According to the gloves(insulating boots) test procedures, read and record the test parameters.
Next: Scope of the insulating boots.
The testing methods andcycles for safety appliances including the insulating boots and the insulating gloves is stipulated in the Safety Code of Electric Power Industry(DL408).
The insulating boots and the insulating gloves are prerequisite appliances for operation and maintenance of the electric power system.
When the steel ball test is installed inside the insulating boot, the sponge can be fully immersed in water.
Start the test, the test steps are the same as the above no-load test, butit should be noted that the test voltage of the insulating gloves is 15kV, and the insulating boots are 18kV;
Put a metal piece in the same size as the boot into the boot, place the high voltage electrode in the insulating boot, and contact the high voltage electrode with the metal sheet.