英語 での Steam generator system の使用例とその 日本語 への翻訳
{-}
-
Colloquial
-
Ecclesiastic
-
Computer
-
Programming
The Steam Generator System.
The present invention includes a method for improving effectiveness of a steam generator system 10.
Reliable steam generator system for humidity applications.
Humidity System choicesare the conditioned fine Mist System or the Steam Generator System.
In one embodiment, the steam generator system 10' includes an infrared sensor 32.
The present inventionalso includes another method for improving effectiveness of a steam generator system 10.
A steam generator system having an improved effectiveness is generally designated by the numeral 10.
The present invention includes a method for retrofitting a steam generator system 100, 100' for improved effectiveness.
In one embodiment, the mitigating the S0 3 in the flue gas mixture includes chemical renderingand/or supplying low sulfur fuel to the steam generator system.
The term"a method for improving effectiveness of a steam generator system," is also referred to as a method for operating a steam generator system.
As the differential temperature DT of the flue gas outlet temperature increases,thermal efficiency improvements of the steam generator system 10, 10' are realized.
In one embodiment, the steam generator system 10' further comprises a flue gas reheat air particulate removal system 33 positioned in and between ducts 64 and 65.
The waste water drying system 77 has utility in reducing or eliminating the amount of liquid effluents from the flue gas desulfurization system 17,while not adversely affecting the heat rate of the steam generator system 10.
The steam generator system 10 includes a steam generator vessel 11 and an air preheater 13(e.g., a rotary regenerative heat exchanger of the inventor's AXRM™ design, AXRM™ is a trademark of Arvos Inc.).
This inability to completely realize the full potential of increasing the efficiency of the APH thereforelimits the ability to increase the thermal efficiency of the steam generator system to be increased to its full potential.
In one such embodiment, the original steam generator system operates with a wet stack limited to flue gas outlet velocities in the order of 55 to 60 feet per second thereby preventing pollutant mist exiting the discharge stack 19.
Challenge The new plant being established in Mexico required a distributed control system to operate the three primary chemical-processing areas used in nitrile production: the reaction system, distillation system andcomplementary services such as the supplying of fatty acids, and the steam generator system.
It will be appreciated therefore that once retrofitted, the steam generator system 10, 10', 10" can operate at higher loads than previously possible resulting in increased steam generation and power output from the steam generator vessel 11.
The steam generator system 10' includes a control unit 71, such as a computer processor, memory and signal processing electronics and the method includes comparing the cold end metal temperature to the water dew point temperature and controlling, with the control unit, the cold end metal temperature above the water dew point in the air preheater 13.
The steam generator control system security protection includes multiple functions such as low water level, overheating, and overpressure etc. to ensure no security risks.