The Arcing Horn is usually installed at both ends of the insulator string.
Insulatorset clamp mainly use to connect insulator string or clamps, to bear mechanical load.
ZBS Clevises are used to attach clevistongue insulators to various associated hardware within an insulator string.
Material stainless steel which guarantee insulator string connection very safety.
Hot-dip galvanized steel, used for insulator string with hardware, wire clip and insulator string, connection between the wire and tower.
Grading& Shielding ringis used to connect Strain Clamp and insulator string in the straight line tower.
Suspension clamp is used to fix the wire on the insulator string of the linear pole, or to hang the lightning rod on the line tower.
MRJ3 Type Spacers are used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines or to grade andto shield the insulator string of 330KV and above transmission lines and substation.
UB type clevisesare mainly suitable for hanging suspension insulator string(composed of suspension insulator& Suspension Clamp) on the conductor subjected to the pole or tower;
DB adjusting plate is applicable to insulation fitting for adjusting the length of twin-connecting orparallel-connecting insulator string through series connection with insulator string.
On the other hand,they are also used for hanging tension insulator string(composed of suspension insulator& tension clamp) on the tension conductor subjected to the pole or tower.
Pt Type AdjustingPlate is exclusively used for twin-connected rotation angle insulator string and tension insulator string.
It is used for ground wire isused to fix& connect conductor onto the tension insulator string or the fittings on pole& tower through sustaining tensile force generated by the conductor.
Ph Type Extension Ring is used to connect suspension insulators into a string and hang the string in tower,is used to connect Strain Clamp and insulator string in the straight line tower.
When an overvoltage accident occurs,the air gap is first worn out by the insulator string, and the arc is leaped from the air without causing the flashover of the insulator. .
It is used for connection between twopieces of separate conductors subjected to twin-connection insulator string(suspension or tension insulator string).
By connecting the wire,the wire and lightning conductor are suspended on the insulator string or the lightning arrester is suspended on the tower.
MRJ spacers are used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines,or to grade the insulator string of 330KV and above transmission lines and substation.
Product name Overhead Hot dip Galvanized Steel Ball Eye Product description Hot dip galvanized steel used forinsulator string with hardware wire clip and insulator string connection between the wire and tower Ball eyes are used to attach ball and….
They are used to restain aeolian vibration of conductor and ground wire for overhead transmission lines,or to grade and to shield the insulator string of 330KV and above transmission lines and substation.
By connecting the wire,the wire and the lightning rod are suspended on the insulator string or the lightning conductor is suspended on the tower.
It is applicable to insulation fittingfor adjusting the length of twin-connecting or parallel-connecting insulator string through series connection with insulator string.
Grading& Shielding ringis used to connect Strain Clamp and insulator string in the straight line tower.
Cross spacer damper is used to restrain aeolian vibration of conductor and ground wire for overhead transmisson lines,or to grade and to shield the insulator string of 330KV and above transmission lines and substation.
Electric Power Fitting protective fittings are used to restrain vibration of conductor and groud wire foverhead transmission lines,or to grade and to shield the insulator string of 330KV and above transmission lines and substation.
FJZ3 Spacer Dampers are used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines,or to grade and to shield the insulator string of 330KV and above transmission lines and substation.
JJB2 spacer damper is used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines,or to grade and to shield the insulator string of 330KV and above transmission lines and substation.
Grading and Shielding Rings are used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines,or to grade and to shield the insulator string of 330 KV and above transmission lines and substation.
Usually, JS spacers are used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines or to grade andto shield the insulator string of 330KV and above transmission lines and substation.
Square Spacer dampers are used to restrain aeolian vibration of conductor and ground wire for overhead transmission lines,or to grade and to shield the insulator string of 330KV and above transmission lines and sunstation.