No partial discharge test transformer.
Why dose transfomer do partial discharge test.
Non-partial discharge test transformer characteristics.
Types and ways of interference in partial discharge tests.
Next: non-partial discharge test transformer characteristics.
There are two types of transformers without partial discharge test.
Inflatable non-partial discharge test transformer characteristics.
Common interference and treatment method for transformer partial discharge test May 31, 2019.
Battery discharge test to ensure the battery is in goodcondition.
HZJF-9041 4-Channel Partial Discharge Test Equipment 1.
Non-partial discharge test transformer characteristics Apr 17, 2018.
Epoxy barrel oil immersed without partial discharge test transformer characteristics.
No partial discharge test transformer classification and use storage precautions.
LIt could save 10 groups of on-line monitoring data and10 groups of discharge test data;
Step 6: Enter into discharge test parameters setup. see details in 3.2.
Energy cables are subject to"go/no-go" withstand tests(to expose defects),tangent delta tests, partial discharge tests, etc.
Automatic discharge test is completed, and real-time monitoring the discharge process.
Interference will reduce the detection sensitivity of the partial discharge test, and the interference level should be suppressed to the minimum level.
The partial discharge test of the transformer is an important measure to ensure its reliable operation.
Device can control center by using P89C668 single chip computer, device can control by upper computer or break away it with the external sampling circuit to complete constant current constant voltage charging,constant current discharge test, capacity sorting work.
Inflatable non-partial discharge test transformer is filled with SF6 gas with high dielectric strength as insulation medium.
Interference sources from the outside, such as high voltage test, nearby switch operation, radio emission and other static or magnetic induction and electromagnetic radiation,can be coupled by the discharge test circuit, and mistaken for the discharge pulse.
Previous: Power frequency without partial discharge test transformers should be precautions before AC withstand voltage test. .
When the string reaches setup value of final discharge voltage, setup value of final discharge capacity, setup value of final discharge time, any cell voltage is below setup value of final cell voltage ormanual final operation could stop discharge test.
One is an inflatable type partial discharge test transformer, and the other is an epoxy barrel oil-immersed type partial discharge test transformer.
We also have an extensive dielectric lab with mains frequency tests, discharge tests, and shock test tests on low- and medium-voltage systems and components are carried out with voltages up to 400 kV.
TSH and perchlorate discharge test in the suspicion of Pendred s syndrome; urine test and renal function test in children with possible Alport s syndrome; an EKG to assess the QT interval in the Jervell s and Lange-Nielsen s syndromes.
In the case of power detection test site use,the commonly used inflatable type partial discharge test transformer is small in size and light in weight, and it is convenient to move to the required position for on-site inspection and test. .
After the test of the transformer without partial discharge test, the effective discharge operation is carried out first, then the grounding rod is hung on the high-voltage output end, and then the sample is removed, the data record during the test is carefully done, and the report is analyzed and the report is analyzed.
High frequency vibration test, aging test, charging and discharging test before delivery.