A RAy unit is then mounted onto the antenna.
Module Alignment displays RSS andSNR for both local and peer RAy unit.
The RAy unit is then mounted on the antenna.
Fig. 4.6: Silicone grease A tub of grease is supplied with each RAy unit.
The RAy unit uses one VLAN id for internal needs.
It needs to be mounted to each antenna according to the instruction manual before mounting the RAy unit.
The RAy unit is grounded to the flange by the Ethernet connector using an M6 screw.
When the time zone and/or daylight saving time is changed, the original values set in the RAy unit are kept.
Grounded RAy unit itself as described in Section 4.3.3,“RAy unit grounding”.
According to the Advanced menu proceeds the deciding,through which port the framework should be transmitted from RAy unit.
The RAy unit has to be grounded before connecting to the power supply and/or to the user network.
AGC cable for connecting a voltmeter to the RAy unit for adjusting the antenna direction. see"Antenna mounting", point g- g.
RAy unit mounting to the antenna Each antenna allows RAy unit to be mounted on it with different polarization.
If a new firmware version is released for thegiven microwave link type, you can upload it to your RAy units.
Each antenna allows RAy unit to be mounted on it with horizontal or vertical RX polarization.
All accessories offered by RACOM for proper installation of the complete RAy link setup(including proper grounding) are tested for compatibility with RAy unit.
Mounting the RAy microwave bridge The RAy unit is grounded to the flange by the Ethernet connector using an M6 screw.
Flexible waveguide mounting kit(other antennas) RAy units can be attached to the antenna using flexible waveguide mounting kits.
Fig. 4.9: Right-side mounting- vertical RX polarization Fig. 4.10:Right-side mounting- horizontal RX polarization RAy unit is fixed to the antenna by 4 pcs.
It enables to double the link capacity by mounting two RAy units on a single antenna with each unit operating in a different polarization.
Should the RAy unit be used with other than recommended accessories, Racom takes no responsibility for any malfunction caused by such accessories.
One 3-pin power plug with screw-terminals is delivered with each RAy unit(see SET-RAY2-CON-B), ready to be mounted to a customer DC cable.
Each RAy unit mounted on an OMT extender provides the same technical parameters and same level of service as a unit mounted directly to the antenna(without OMT between) except when both RAys are transmitting and receiving data on identical channels on identical frequencies.
Licensed bands(10, 11 and 18 GHz)require one RAy unit(labeled L) to transmit in the Lower and receiving in the Upper part of the band.
Installation of Jirous antennas ANT-JRM-inst. pdf10 4 pcs M8x30(Allen)screws to mount the RAY unit to the antenna are part of the antenna delivery.
Fig. 4.5: Grease points on the antenna pivot andRAy unit bushing Lubricate both the internal area of the bushing on the RAy unit(2) and the"O" ring(1) with a thin even layer that allows the pin to slide easily into the bushing without damaging the"O" ring.
Antenna waveguide Fig. 1.2:Waveguide pivot RAy2 link requires the use of external parabolic antenna for each RAy unit- both for physical mounting as well as for the wireless transmission itself.
CAB-CAT5E-FTP-TLD Cat.5e cable for connecting RAy units to the network, outdoor, UV protected, -40 C až +70 C, TELDOR Datasheet17 orig. part no.