Examples of using Crest factor in English and their translations into German
{-}
-
Colloquial
-
Official
-
Ecclesiastic
-
Medicine
-
Financial
-
Ecclesiastic
-
Political
-
Computer
-
Programming
-
Official/political
-
Political
Current crest factor 4 or less.
The output inverter andthe output filter circuit provide high peak currents crest factor 3.
Non-linear load, crest factor 3:1.
The Crest Factor is defined as the relationship between the Peak Value of a signal and its.
Weight 152 kg 335 lb 1 SPL max peak test signal:pink noise with crest factor 42 dimensions without wheels.
The Crest Factor of an amp represents the relation between the peak voltage and the RMS value.
For a sinusoidal alternating voltage withan RMS of 230V and a peak of 325V the crest factor is 1.41.
The crest factor means the ratio of the peak voltage to the RMS voltage.
For non-sinusoidial waveforms,add±(2% of reading+ 2% full scale) typical, for crest factor up to 3.
Crest Factor:< 2: 1 at full scale&< 4: 1 at half scale ACV AutoVATM Threshold: 30VAC(40Hz~ 500Hz only) nominal.
HF voltage form unmodulated sinusoidal AC voltage Rated frequency 350kHz(at RL 500 ohms)± 10% Crest factor 1.4(at RL 500 ohms) Max.
Hz- 1 kHz; TrueRMS; 400 Hz; Effective average Crest factor max. 3.0 at Sinus voltage; Overload protection 600 V Overload protection 600 V.
Measuring of: voltage, current, average and peak current, effective power, idle power, apparent power,power factor, crest factor.
Standard mode 2 INFRA mode3 SPL max peak test signal:pink noise with crest factor 44 standard mode 5 INFRA mode 6 dimensions without wheels Downloads.
Frequency of the alternating current: 50Hz to 400Hz Overload protection see below Indication at theVC-840 as true effective value(True Rms), crest factor max.
Frequency range: 45- 400 Hz; overload protection: 600 V; impedance:10 MΩ Crest factor(CF): CF 1.0- 2.0:+ 3% deviation CF 2.0- 2.5:+ 5% deviation CF 2.5- 3.0:+ 7% deviation.
However, the effective performance depends on many different parameters: operating voltage, impedance of the speakers,cooling and the crest factor of the music.
Maximum Crest Factor< 1.4: 1 at full scale&< 2.8: 1 at half scale, and with frequency components within the specified frequency bandwidth for non-sinusoidal waveforms.
HF voltage form unmodulated sinusoidal AC voltage Rated frequency 350 kHz 350kHz(at RL 500 ohms)± 10% Crest factor 1.4(at RL 500 ohms) Rated load resistance 75 ohms Max.
In addition to spectral analysis via FFT or using, for instance, an envelope spectrum, it is possible to calculatekey statistical values such as the kurtosis or the crest factor.
The webinar explains the key issues of audio signal generation,covers related issues such as Crest factor or level units, and provides practical examples.
Watts rms(8 hours of 6 dB crest factor pink noise, 1,000 to 10,000 Hertz) 60 watts rms 2 hours of 6 dB crest factor pink noise, 1,000- 10,000 Hertz, AES method.
The value supplied corresponds to the RMS power required of the amplifierin order to supply the test signal(pink noise with crest factor 2) utilised to measure AES power.
Maximum Crest Factor< 2.5:1 at full scale and< 5:1 at half scale or otherwise specified, and with frequency spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms.
With low-pass filter(V.F.C):±(4.0%+ 10) Overload protection: 100 A; frequency range 50- 60 Hz;TrueRMS Crest factor(CF): CF 1.0- 2.0:+ 3% deviation CF 2.0- 2.5:+ 5% deviation CF 2.5- 3.0:+ 7% deviation.
Crest Factor Crest Factor is the ratio of the Crest(instantaneous peak) value to the True RMS value, and is commonly used to define the dynamic range of a True RMS DMM.
Deruty and Damien Tardieu criticized Sreedhar's methods inan AES paper, saying that Sreedhar had confused crest factor(peak minus RMS) with dynamics in the musical sense"pianissimo" to"fortissimo.
Watts rms(8 hours of 6dB crest factor pink noise, 40- 400 Hertz) 375 watts rms(2 hours of 6dB crest factor pink noise, 40- 400 Hertz) Recommended amplifier power capability- 600 watts rms maximum into 8 ohms per LF-3115.
True RMS Ranges: 200µA, 2, 20, 200mA, 20A* *.15 to 20A for 30 sec max Resolution, 200µA range: 10nA Accuracy(50Hz .1 kHz), 200µA to 200mA rgs:±(0.8% rdg+ 10 dgt) 20A rg:±(2.5% rdg+ 10 dgt) Conversion: AC coupled,True RMS responding Crest Factor for True RMS: 5 :1 Burden Voltage: 200µA to 20A ranges: 350mVDC 200mA range: 650mVDC 20A range: 850mVDC OL Protection, mA input: 0.5A/250V fast blow ceramic fuse 20A input: 20A/600V fast blow ceramic fuse.
Even though their standards specify far higher crest factors, the industry strives for crest limitation for economic reasons, so that the resulting correction doesn't exceed a factor of 10.