Examples of using Open-loop in English and their translations into Japanese
{-}
-
Colloquial
-
Ecclesiastic
-
Computer
-
Programming
Output short-circuit and open-loop protection.
Open-loop systems are simply and fast way of water heating.
For more information about open-loop transfer, click here.
You can use open-loop transfer to diagnose SDS hardware setup problems.
This phenomenon causes undesirable behavior in open-loop position control.
Figure 3. Simulated open-loop gain and phase for step-down converter.
The MAX4236 and MAX4237 have a typical large-signal, open-loop voltage gain of 120dB.
Open-loop systems are not recommended in regions where water quality is not good enough.
Control Method V/f control, open-loop vector, closed loop vector, drives with encoders.
Open-loop Method(Control) One of control methods in which only indications are made without feedbacks.
The process can be implemented using an open-loop technique, independently of the system control loop.
If open-loop transfers work but closed-loop transfers do not, you may have one of the following problems.
Stepping technology allows for the use of an open-loop controller- simplifying machine design and.
The rate of the open-loop torque control is slower than the rate of the closed-loop current control.
With a wide dynamic range of 92 dB, the device allows the user to measure even thesmall input signals experienced in high-gain, open-loop circuits.
Dwolla creates an end-to-end, open-loop payment solution for anything connected to the Internet.
Open-Loop Position Control of a Stepper Motor: New in Wolfram Language 12 In open-loop control, the controller performs a control action without any feedback from the response of the system to the control action.
COSYM can be used for both closed-loop and open-loop testing, and it is possible to simulate discrete-time as well as continuous-time systems.
The open-loop gain and phase plot from the model shows a crossover frequency of about 70kHz and a phase margin of 56 degrees.
They can be each used as an external power supply incases where the current is inadequate for an open-loop operation or with a driver contained in the controller.
Negative feedback and high open-loop gain cause the voltages at the amplifier input terminals, VA+ and VA-, to be essentially equal.
A thorough analysis of each situation should be performed, but some of the variables,such as open-loop output resistance, are difficult to confirm from data sheet specifications.
Features: Open-loop control, easy handle, economy, small angle error, brushless design, long service life and low speed with high torque output.
The Control subsystem uses an open-loop approach to control the IPMSM torque and a closed-loop approach to control the current.
The open-loop output resistance of the op amp is included to allow for the situation when ROOL becomes close in value to RΘ at high frequencies as the loop gain rolls off.
The MAX4310-MAX4315's internal amplifiers maintain an open-loop output impedance of only 8Ω over the full output voltage range, minimizing the gain error and bandwidth changes under loads typical of most rail-to-rail amplifiers.
Our open-loop decentralized ecosystem Gabro aims to provide consumers with the ability for instant redemption and manage multiple loyalty point and exchange them freely on a single blockchain enabled platform.
Assuming infinite open-loop gain from an ideal op amp, voltage gain is: Rearranging the output impedance into the gain equation: In general.
Consequently, open-loop cooling systems have been banned and the water from the machine cooling systems is permanently recycled on all the Group's sites.
When the open-loop amplifier is within its specified IVR, the differential input signal(VIN+- VIN-) is 180 degrees out of phase with VDIFF.