This Methane Detection Probe.
Detection Probe(for gas bumers).
Safely check the methanecontent in the air beyond roof support with the Methane Detection Probe.
Flammable gas detection probe should be installed when the sensor down fixed.
Complex gas compositions andconcentrations are detected by replacing different gas detection probes.
The combustible gas detection probe shall be mounted with the sensor facing down.
Gas detection probe should be wired in the case of power to determine the correct wiring after the power;
A handheld gamma counter(represented by any handheld gamma detection probe) was used intraoperatively to identify sentinel lymph nodes localising technetium Tc 99m.
Gas detection probe wiring should be used three-core shielded cable, a single wire diameter greater than 1 square millimeter, wiring shield must be grounded.
Featuring an aluminum five section extending pole with locking collars, and an extendable instrument snout,the Methane Detection Probe from Johnson Industries is a versatile tool that will help ensure the safety of your facility and your employees.
Combustible gas detection probes should be under the condition of power wiring, determine the correct wiring after electricity;
When the leakage occurs and the water over the detection probe, ezSensor Water can detect the leakage quickly and send a signal to ezAlert, then ezAlert will send a message to the EZVIZ APP.
Gas detection probe should be installed when the sensor down, the lock nut should be fully tightened, the probe cover should be completely covered, with a screw tightened to meet the explosion requirements.
Combustible gas detection probe when installation should be fixed sensor downwards.
This Methane Detection Probe can be steered to an exact location at the face of a coal mine, assuring accuracy, quality, and safety for your facility and mining site.
The combustible gas detection probe should be wired through the pipe, and the pipe should meet the fire protection requirements.
Combustible gas detection probe for large area gas detection can be used when 10 to 12 square meters a probe layout, but also to detect the alarm effect.
The gas leak detection probe is capable of detecting either methane(CH4) or propane(C3H8) in a concentration range from just a few ppm up to 10,000 ppm, depending on your choice.
Combustible gas detection probe used for large area of gas detection can be used when 10~ 12 square metre a probe to decorate, also can achieve detection alarm.
Combustible gas detection probe on-site alignment should wear pipe, the pipe should be used to meet the fire requirements, the pipe should be connected with the probe to meet the fire requirements.
Combustible gas detection probe installation height:detection of hydrogen, natural gas, city gas and other specific gravity is less than the air gas, the use of about 1 meter from the roof to install;
Combustible gas detection probe field line should wear tube, pipe used shall conform to the requirements of the fire, the pipe should be connected to the probe and to meet the requirements of fire control.
When the gas detection probe is used for large-area gas detection, it can be arranged with a probe of 10 12 square meters, which can also achieve the detection and alarm effect.
Combustible gas detection probe installation can be used roof roofing, wall installation or pipe installation, should ensure that the installation of solid and reliable, should be considered easy to maintain, calibration.
D gas detection probe when installation should be sensor fixed down and lock nut should fully tightened, probe should be completely cover cover good, with screw, in order to achieve the explosion-proof requirements.
Gas detection probe installation can be used roof roofing, wall installation or pipe installation, should ensure that the installation of solid and reliable, should be considered easy to maintain, calibration.
Flammable gas detection probe selection should be selected valve, pipe interface, outlet or easy to leak near the radius of 1 meter range, as close as possible, but do not affect other equipment operation, while avoiding high temperature, high humidity environment.
Combustible gas detection probe study should choose valve, the pipeline interface, near the outlet or easy to leak, within the range of 1 meter as near as possible, but do not affect other equipment operation, avoid high temperature and high humidity environment at the same time.
A gas detection probe study should choose valve, the pipeline interface, near the outlet or easy to leak, within the range of 1 meter as near as possible, but do not affect other equipment operation, avoid high temperature and high humidity environment at the same time, to avoid external influence, such as splashing water, oil, and the possibility of mechanical damage.
Gas detection probe selection should be selected valve, pipe interface, outlet or easy to leak near the radius of 1 meter range, as close as possible, but do not affect other equipment operation, while avoiding high temperature, high humidity environment, to avoid the external Affect the possibility of splashing water, oil and causing mechanical damage.