Limits of additional error M1619.1 caused by.
However, in large fragments it worsens the readability,and leads to additional errors.
The limit of additional error TS1626.1 caused by.
The electromagnetic compatibility(EMC) of the equipment shall be on a level as to minimize additional errors.
Maximum permissible additional error C1627 caused by.
The electromagnetic compatibility(EMC)of the equipment shall be on a level as to minimize additional errors.
Maximum permissible additional error of the instrument must be equal in the relationship.
Psychrometer should be placed in a horizontal position so thatthe cold air on the wet thermometer does not hit the dry bulb thermometer and introduce additional error.
Blocking older versions of browsers will eliminate the additional errors and simplify the work of your technical support.
Admissible additional error of the instrument under the influence of an external magnetic field with induction of 0.5 mT is half the permissible basic error. .
When using resistance temperature detectors(RTDs) for temperature measurement, the additional error can be introduced by connection wires, as wires have their own resistance which depends on the ambient temperature.
Admissible additional error caused by the deviation of the ambient temperature of(20± 5) C and any at 10 K does not exceed± 0,8%- for ammeters, kiloampermetry M1621.
He neglected the precaution of obtaining confirmation of his sovereignty at Rome, and made the additional error of offending Publius Clodius Pulcher, by failing to ransom him when he had fallen into the hands of Cilician pirates.
Admissible additional error frequency TS1626 under the influence of external magnetic field induction 0.5 mT formed by a DC or AC rated frequency shall not exceed± 1,5% of full scale range.
When measuring the voltage and time intervals,the limit of additional error N3015 appliance, rejecting the supply voltage of± 10% of normal or ambient temperature deviations of± 10 C from the normal value should be equal to half the value of the maximum permissible primary error. .
Additional errors of fact included the portrayal that Moe Howard was down on his luck after Columbia cancelled their contract and worked as a gofer at the studio, where he, his brothers and Larry had formerly worked as actors.
The limit of additional error instrument kit K54 caused by a deviation from the provisions set K54 normal in any direction at an angle of 5, and is equal to the limit of permissible basic error. .
The limit of additional error instrument kit K54 caused by the installation of a set based on the thickness of the ferromagnetic(2± 0,5) mm is equal to half of the maximum permissible basic error. .
Limits additional error dynamometer DPU-20-2 2t(20kN), due to changes in ambient temperature in the operating temperature range, other than the normal temperature conditions, the basic error of 0.25 for every 10 º C;
Admissible additional error response contact device ammeter device C324K induced changes in supply voltage circuit pin device in the range of -15% to +10% of the nominal value or the frequency of± 2% of the normal value is± 2,5%;
Admissible additional error of the instrument under the influence of an external magnetic field induction 0.5mTl frequency equal to the frequency of the current flowing through the measuring circuits, does not exceed 0,4 admitted basic error. .
Admissible additional error frequency TS1606 under the influence of external magnetic field with the induction of 0.5 mT formed by a DC or AC of the same frequency as the frequency of the voltage that is supplied to the instrument is admitted basic error. .
The limit of additional error instrument kit K54 caused by changes in temperature, ambient temperature from normal to any temperature within the operating range of 10 to 35 C, equal to the limit of permissible basic error for every 10 C change in temperature.
The limit of additional error power meter kit K54 caused by the influence of power factor is equal to the limit of permissible basic error in the normal range of frequencies and twice the limit of permissible basic error in the working frequency range.
The basic and additional errors are normalized without errors measuring current and voltage transformers, and are expressed as a percentage of full scale measurement range, and for wattmeters and varmetrov with two-scale- from the sum of absolute values of end of range;
Basic and additional errors are normalized, excluding errors of measuring current and voltage transformers, and are expressed as a percentage of the final value of the measuring range, and for wattmeters and varmeter with double-sided scale- of the modules of finite values range;
Admissible additional error frequency TS1606 caused deviation of the ambient temperature(20± 2) º C to any temperature from -40 C to +50 C and up to any in the range of -10 C to +55 C( for devices in tropical version) for every 10K is 0.5 Acceptable basic error. .
Limits of additional error appliances kit K54 from the influence of external homogeneous magnetic field induction of 0.5 mg, sinusoidally varying, in time with a frequency equal to the frequency of the current flowing through the measurement, the test kit K54 circuits, in the most unfavorable direction of the magnetic field and phase 1, 5% of the final value of the measuring range.
Admissible additional error devices TS1620 ammeter, voltmeter TS1620, kiloammeter TS1620, TS1620 milliammeter caused deviation from normal temperature for every 10 K, equal to half the permissible basic error, under the influence of an external alternating magnetic field induction 0.5 mT, with a frequency that matches the frequency of the current flowing through the measuring circuits devices is± 1,5% of full scale range.