Maximum luminous intensity in cd.
A headlamp with a gasdischarge passing beam and a driving beam with a maximum luminous intensity comprised between 123625 and 145125 candelas… as above.
Maximum luminous intensity in cd when used as.
In the case of reciprocally incorporated headlamps, indication of the maximum luminous intensity of the driving beams as a whole shall be expressed as above.
Maximum luminous intensity in cd outside the 10°-field.
A headlamp with a passing beam designed for both traffic systems anda driving beam with a maximum luminous intensity comprised between 80625 and 96750 candelas… or.
Maximum luminous intensity in cd when used as.
A headlamp, Class B, emitting a passing beam anda driving beam with a maximum luminous intensity between x and y candelas, meeting the requirements of this Regulation.
The expert from GTB presented document TRANS/WP.29/GRE/2002/14 on the safe installation of reversing lamps with regard to the new value for the maximum luminous intensity.
The reference mark(I'M) of the maximum luminous intensity, referred to in paragraph 6.3.3.2. above, shall be obtained by the ratio.
A headlamp emitting a halogen passing beam designed for both traffic systems anda halogen driving beam with a maximum luminous intensity between x and y candelas, meeting the requirements of Regulation No. 8 and.
The reference mark(I'M) of the maximum luminous intensity(IM), referred to in paragraph 4.2.2.6. and 6.3.3.1. or 6.3.3.2. shall be obtained by the ratio.
On headlamps meeting the requirements of this Regulation in respect of the driving beam,an indication of the maximum luminous intensity expressed by a reference mark as defined in paragraph 6.3.2.2. below, placed near the circle surrounding the letter"E";
A headlamp emitting a driving beam for both traffic systems with a maximum luminous intensity comprised between w and z candelas, meeting the requirements of Regulation No. 20, the maximum luminous intensity of the driving beams as a whole being comprised between 86,250 and 111,250 candelas.
On Class D headlamps meeting the requirements of this Regulation in respect of the driving beam,an indication of the maximum luminous intensity expressed by a reference mark, as defined in paragraph 6.3.2.1.2. below, placed near the circle surrounding the letter"E";
A headlamp, Class C, with a passing beam anda driving beam with a maximum luminous intensity comprised between 33,750 cd and 45,000 cd(as indicated by the number 12.5), approved in Germany(E1) in accordance with the requirements of this Regulation in its original form(00), which is reciprocally incorporated with the same front position lamp as above;
The installation unit 1(or 2) of the system bearing the above approval marks meeting the requirements of this Regulation(00 series of amendments) in respect of both a class C passing beam for left-hand traffic anda driving beam with a maximum luminous intensity comprised between 123,625 and 145,125 candelas(indicated by the number 30), grouped with a front direction indicator lamp of category 1a, approved in accordance with the 01 series of amendments of Regulation No. 6.
A headlamp, Class C, with a passing beam anda driving beam with a maximum luminous intensity comprised between 48,375 and 64,500 candelas(as indicated by the number 12.5), approved in Germany(E1) in accordance with the requirements of this Regulation as amended by the 01 series of amendments, which is reciprocally incorporated with the same front position lamp as above;
On HSB optical units meeting the requirements of this Regulation in respect of the driving beam,an indication of the maximum luminous intensity expressed by a reference mark, as defined in paragraph 8.3.2.1.2. below, placed near the circle surrounding the letter"E"; 5.2.2.6.
A headlamp emitting a gas discharge driving beam with a maximum luminous intensity comprised between w and z candelas, meeting the requirements of this Regulation in its original form, the maximum luminous intensities of the driving beam contributors as a whole being comprised between 86,250 and 101,250 candelas as shown by the number 30.
On an installation unit contributing to fulfill the requirements of this Regulation in respect of the driving beam,an indication of the maximum luminous intensity expressed by the reference mark, as defined in paragraph 6.3.2.1.2. below, placed near the circle surrounding the letter"E"; 4.2.3.
A headlamp emitting a gas discharge driving beam with a maximum luminous intensity comprised between w and z candelas, meeting the requirements of this Regulation, as amended by the 01 series of amendments, the maximum luminous intensities of the driving beam contributors as a whole being comprised between 123,625 and 145,125 candelas as shown by the number 30.
On an installation unit contributing to fulfill the requirements of this Regulation in respect of the driving beam,an indication of the maximum luminous intensity expressed by the reference mark, as defined in paragraph 6.3.2.1.3. below, placed near the circle surrounding the letter"E"; 4.2.3.
A headlamp with a gasdischarge passing beam and a driving beam with a maximum luminous intensity comprised between 123,625 and 145,125 candelas(as indicated by the number 30), designed for both traffic systems and approved in the Netherlands in accordance with the requirements of this Regulation, as amended by the 01 series of amendments, which is reciprocally incorporated with the same front position lamp as above.
A headlamp, Class B,emitting a driving beam designed for both traffic systems with a maximum luminous intensity between w and z candelas, meeting the requirements of this Regulation, the maximum luminous intensities of the driving beams as a whole being comprised between 86 250 and 101 250 candelas.
Either A headlamp, Class D, with a passing anda driving beam with a maximum luminous intensity comprised between 86 250 and 101 250 candelas(as indicated by the number 30), approved in Germany(E1) in accordance with the requirements of this Regulation in its original form(00), which is reciprocally incorporated with a front position lamp approved in accordance with Regulation No. 50 in its original form(00);
A headlamp, Class B,emitting a driving beam designed for both traffic systems with a maximum luminous intensity between w and z candelas, meeting the requirements of this Regulation, the maximum luminous intensities of the driving beams as a whole being comprised between 123625 and 145125 candelas.
Either A headlamp, Class B, with a passing beam designed for both traffic systems anda driving beam with a maximum luminous intensity comprised between 123625 and 145125 candelas(as indicated by the number 30), approved in Germany(E1) in accordance wit the requirements of this Regulation in its original form 00.
Or A headlamp, Class A, with a passing beam designed for both traffic systems anda driving beam with a maximum luminous intensity comprised between 33750 cd and 41250 cd(as indicated by the number 12.5), approved in Germany(E1) in accordance with the requirements of this Regulation in its original form 00.
Or A headlamp, Class A, with a passing beam designed forboth traffic systems and a driving beam with a maximum luminous intensity comprised between 33 750 cd and 45 000 cd(as indicated by the number 12.5), approved in Germany(E1) in accordance with the requirements of this Regulation in its original form 00.