Примеры использования To standard conditions на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
Correcting the volume to standard conditions.
The knot of gas- a set of measuring instruments and auxiliary equipment designed to measure the volume of gas,reduced to standard conditions.
Correction of Volume to Standard Conditions.
These comprise a unit converter and tools for calculating filter cartridge life with/without B-KOOL, filling time and condensate volume,as well as converters from free air delivery volumes to standard conditions.
Volume measured and reduced to standard conditions.
Limit values, expressed as mg/m3,refer to standard conditions(volume at 273.15 K, 101.3 kPa, dry gas) and are calculated as an average value of one-hour measurements, covering several hours of operation, as a rule 24 hours.
Volume measured and reduced to standard conditions para. 1.
Is either the dilution air or the dilution tunnel background particle concentration, as permitted by the responsible authority, in particles per cubic centimeter,corrected for coincidence and to standard conditions(273.15 K and 101.325 kPa);
The diluted exhaust gas volume, V, shall be corrected to standard conditions according to the following equation.
Where they are not held at a known constant level at the point at which PNC flow rate is controlled, the pressure and/or temperature at inlet to the PNC shall be measured andrecorded for the purposes of correcting particle concentration measurements to standard conditions.
All measurements were expressed corrected to standard conditions dry gas, 273 K, 101.3 kPa and 10 per cent O2.
Determination of corrected stopping distance compared to standard conditions.
The flow test results must be corrected to standard conditions: air pressure of 100 kPa absolute and temperature of 15 °C.
Page 8 conversion of the results of the tests to standard conditions.
The measured volume flow can always be calculated to standard conditions using the input of temperature and pressure sensors, which can be directly connected to the device.
Correction of the diluted exhaust-gas volume to standard conditions.
Emission values expressed as milligram per cubic metre(mg/m3)refer to standard conditions(volume at 273.15 Kelvin(K), 101.3 kilopascal(kPa), dry gas) not corrected for oxygen content unless otherwise specified, and are calculated in accordance with the draft European Committee for Standardization(CEN) standard and, in some cases, national sampling and monitoring techniques.
Correction of the diluted exhaust-gas volume to standard conditions.
For commercial recording of gas consumption natural gas is reduced to standard conditions using flow corrector at customer's option: Floboss 107, SuperFlow, ERZ 2004, etc.
Daily volumetric gas discharge nominal value,m3/24h, normalized to standard conditions.
Average corrected concentration of particles from the diluted exhaust gas corrected to standard conditions(273.2 K and 101.33 kPa), particles per cubic centimetre.
Where they are not held at a known constant level at the point at which PNC flow rate is controlled, the pressure and/or temperature at inlet to the PNC must be measured andreported for the purposes of correcting particle concentration measurements to standard conditions.
If a heat exchanger is not installed upstream of the ultrasonic flow meter,the flow rate of the diluted exhaust, corrected to standard conditions shall be maintained at a constant level during the test.
Where they are not held at a known constant level at the point at which PNC flow rate is controlled, the pressure and/or temperature at inlet to the PNC shall be measured andreported for the purposes of correcting particle concentration measurements to standard conditions.
The flow test results must be corrected to standard conditions.
The conditions for the test should be arranged so that the air temperature andthe humidity measured at the engine intake is set to standard conditions during the test run.
Is the volume of the diluted exhaust gas expressed in litres per test and corrected to standard conditions(273.15 K and 101.325 kPa);
A discrete measurement of particle concentration in the dilutedgas exhaust from the particle counter, corrected for coincidence and to standard conditions 273.2 K and 101.33 kPa.
Vmix volume of the diluted exhaust gas expressed in litres per test and corrected to standard conditions 273.2 K and 101.33 kPa.
Cs, i a discrete measurement of particle concentration in the dilutedgas exhaust from the particle counter, corrected for coincidence and to standard conditions(273.2 K and 101.33 kPa), particles per cubic centimetre.