The mean R coefficient was then calculated for two evaporators.
If two evaporators are used, then each has its own thermostat.
R is the mean relative refrigeration rate for a configuration of two evaporators.
If two evaporators are used, each of them will have its own thermostat.
If the multi-temperature unit can be operated with more than two evaporators.
The tank comes with two evaporators with temperature control support.
Determination of the effective capacity of each evaporator for a configuration of two evaporators.
For a configuration of two evaporators, the effective capacity for each evaporator is calculated as follows.
Determination of the relative refrigeration rate of the unit for a configuration of two evaporators.
The combination of the condensing unit and two evaporators shall be tested with a combination of two evaporators: the largest and smallest;
Measurement of effective capacities andrelative refrigeration rate R for a configuration of two evaporators.
The relative refrigeration rate(R) shall be determined for a configuration of two evaporators and for a configuration of three evaporators where applicable.
If the multi-temperature liquefied gas refrigeration unit can be operated with more than two evaporators.
The effective capacities shall be calculated for each evaporator in a combination of two evaporators and, if necessary, in a combination of three evaporators. .
The effective capacities of each evaporator at -10° C are then interpolated for a configuration of two evaporators.
If the multi-temperature liquefied gas refrigeration unit can be operated with more than two evaporators.
All these problems were solved by vertical placing of two evaporators inside display case operating in the regulatory system«cross» and the built-in refrigeration unit managed from its pressure switch with the ability to control the boiling temperature.
In addition, on demand of the manufacturer, the host unit can be tested optionally with a combination of two evaporators: the largest and the smallest.
If the number of tested evaporators is higher than three,condensing units for a maximum of two evaporators are tested with the largest and smallest evaporator and condensing units for three or more evaporators with the largest, the smallest and a mid-sized evaporator. .
In addition, on the request of the manufacturer, the host unit may be tested with a combination of two evaporators: the largest and the smallest.
In the case of condensing units with three evaporators the third evaporator is cooling under thermostatic control at 0°C with a fixed heat load of 20% of the nominal cooling capacity of the host unit at 20°C. The cooling andheating capacities have to be tested for each evaporator two tests for condensing units with two evaporators, three tests for condensing units with three evaporators. .
In addition, on demand of the manufacturer, the host unit can be tested optionally with a combination of two evaporators: the largest and smallest.
The useful cooling capacities of the evaporators in multi-temperature operation as prescribed in paragraphs 65 and66 are tested with two or three evaporators.
The tests must be carried out on a complete operating multi-temperature unit with two or three evaporators.
The tests must be carried out on a complete operating multi-temperature unit with two or three evaporators.
Multi-temperature operation: Operation of a multi-temperature mechanical refrigeration unit with two or more evaporators working at different temperatures in multi-compartment equipment.
This test shall be conducted with two or three evaporators including the smallest, the largest and, if necessary, a mid-sized evaporator. .
Multi-temperature operation: Operation of a multi-temperature mechanical refrigeration unit with two or three evaporators operating at different temperatures in multi-compartment equipment;
Effective refrigerating capacity: Refrigerating capacity of each evaporator with the condensing unit in multi-temperature operation with two or three evaporators set at different temperatures;