Sample flow from a CVS with a heat exchanger.
FM3 flow measurement device(Figures 14 and 15) particulate sample flow.
Sample flow from a CVS without a heat exchanger.
Mass of particulates corrected for extraction of particle number sample flow.
The sample flow rate is controlled by the flow controller FC3.
Compensating for particle number sample flow- full flow dilution systems.
Qmp sample flow of exhaust gas into partial flow dilution system kg/s.
Compensating for particle number sample flow- partial flow dilution systems.
Qmp sample flow of exhaust gas into partial flow dilution system, kg/s.
The standard error of the estimate, SEE, of the sample flow rate versus the total flow rate shall be determined.
The sample flow into DT is the difference of the total flow and the diluent flow. .
Normally the gas flow rate is higher than the probe sample flow rate and the excess is overflowed out the inlet of the probe.
The sample flow into DT is the difference of the total flow and the dilution airflow.
The gas samples shall be collected in sampling bags of sufficient capacity not to impede the sample flow.
The sample flow into DT is the difference of the total flow and the dilution airflow.
CVS flow rates shall be set according to paragraph 3.3.4. of Annex 5, and sample flow rates shall be set to the appropriate levels.
The sample flow into DT is the difference of the total flow and the dilution air flow. .
Carefully install a clean particulate filter in each of the filter holders andinstall assembled filter holders in the sample flow line.
The sample flow rates shall be adjusted to desired levels, using bypass flow, if desired.
The dilution air flow rate is usually constant whereas the sample flow rate is controlled by the flow controller FC3.
Adjust the sample flow rates to the desired flow rate and set the gas flow measuring devices to zero.
Can automatically control the distillation heating circuit,and makes the sample flow rate control from the initial distillation point to 95% within 4~ 5 ml per minute.
A sample flow alarm to monitor the sample flow and alarm when the flow falls below a defined level.
When extracting from a varying flow rate, the sample flow rate shall be varied in proportion to the varying flow rate;
The sample flow into the dilution tunnel DT is the difference of the total flow and the dilution air flow. .
In this case,a pre-test shall be run, and the exhaust mass flow signal of the pre-test be used for controlling the sample flow into the particulate system.
Adjust the sample flow rates to the desired flow rate and set the CVS gas flow measuring devices to zero.
For dilution air and dilute exhaust mixture of sufficient capacity so as not to impede normal sample flow and which will not change the nature of the pollutants concerned.
The PM sample flow from the dilution tunnel shall be measured with an accuracy of+- 2.5 per cent of reading or+- 1.5 per cent full scale, whichever is the least.
In this case,a pre-test shall be run and the exhaust mass flow signal of the pre-test be used for controlling the sample flow into the particulate system.