Old para 15 is deleted.
Amended paragraph old para. 5.
Old para. 55. Test conditions.
The second sentence of old para 8. is deleted.
Old paras. 29.(d) and 30. are deleted.
Replaces old subprogramme 7; old paras. 15.35-15.38 are replaced by the new paragraphs below.
Old para. 49(b) Mechanically refrigerated equipment.
New Part D( Checking equipment in service)is added and includes the old paras. 29 and 49. Now 44 and 45.
Old paras. 15.25-15.29 are replaced by the new paragraphs below.
Replaces old subprogramme 1; old paras. 8.8-8.11 are replaced by the new paragraphs below.
Old para 29(b) Examination for air-tightness not applicable to tank equipment.
Replaces old overall orientation; old paras. 23.1-23.6 are replaced by the new paragraphs below.
Old para 49(a) Refrigerated equipment other than equipment with fixed eutectic accumulators.
Replaces old subprogrammes 2 and 4; old paras. 15.12-15.15 and 15.20-15.24 are replaced by the new paragraphs below.
Old para 14. The mean outside temperature and the mean inside temperature of the body shall each be read not less than four times per hour.
The Office of the Special Adviser on Africa provides overall coordination andleadership of the programme. replaces old para. 8.7.
Replaces old subprogramme 1,Promotional services; old paras. 23.7-23.13 are replaced by the new paragraphs below.
Old para 2. The mean surface area S of the body is the geometric mean of the inside surface area Si and the outside surface area Se of the body.
A test report of the type appropriate to the equipment tested shall be drawn up for each test in conformity with one or other of the models 1 to 6 hereunder. from old para. 60.
Old para 35. The mean outside temperature and the mean inside temperature of the body shall each be read not less often than once every 30 minutes.
Temperature measuring instruments protected against radiation shall be placed inside and outside the body at the points specified in paragraphs 1.3 and1.4 of this appendix. old para 11.
Old para 33. Temperature measuring instruments protected against radiation shall be placed inside and outside the body at the points specified in paragraphs[1.3 and 1.4] of this appendix.
Old para 13. When continuous operation has been established, the maximum difference between the temperatures at the warmest and at the coldest points on the outside of the body shall not exceed 2 K.
Old para 47., last sentenceThe test shall be deemed satisfactory if the heating appliance is able to maintain the prescribed temperature difference during the 12 hours aforesaid.
Old para 22. The appliances for heating and circulating the air and for measuring the quantity of heat exchanged and the heat equivalent of the aircirculating fans shall be started up.
Old para 12. The appliances for generating and distributing cold or heat and for measuring the quantity of cold or heat exchanged and the heat equivalent of the aircirculating fans shall be started up.
From old para. 53.[The same procedure shall be followed for the enthalpy method described below, but in this case the heat power dissipated by the evaporator fans at each temperature level must also be measured.] last sentence of para. 56.
Old para 38. When the mean inside temperature of the body reaches the mean outside temperature(+30°C), the doors, hatches and other openings shall be closed and the refrigerating appliance and the inside ventilating appliances(if any) shall be started up at maximum capacity.
Old para 32 The empty equipment shall be placed in an insulated chamber whose mean temperature shall be kept uniform, and constant to within+- 0.5[K], at+ 30 C. The[mass of air in] the chamber shall be made to circulate as described in paragraph[2.1.5] of this appendix.
Old para 36, first sentence The test shall be continued for 12 hours after the mean inside temperature of the body has reached the lower limit prescribed for the class to which the equipment is presumed to belong(A+ 7 C; B 10 C; C 20 C; D 0 C) or, in the case of equipment with fixed eutectic plates, after stoppage of the cooling appliance.