Примеры использования Secondary windings на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
The number of secondary windings- 2;
The primary coil, which produces an inhomogeneous magnetic field,is several times shorter than the secondary windings.
Readings from the LVDT secondary windings are changing more rapidly than expected.
As core position changes with liquid level, voltages are induced in the secondary windings of the LVDT.
Crosses the primary and secondary windings and produces the spark at top dead center of the piston.
The work with the load test hexagon should be carried out for all secondary windings of the CT.
In the device the primary and secondary windings are connected directly, and have thereby not only magnetic coupling, but also electricity.
LVDTs, RVDTs and resolvers measure the change in inductive coupling between coils,usually referred to as primary and secondary windings.
The power frequency withstand voltage standard between the secondary windings of the transformer and its shell is 2kV, which can be replaced by 2500V megohmmeter.
Among the ignition coil failures, there are such faults as insulation breakdowns andturn-to-turn short circuits of the primary and secondary windings.
This device allows you to connect ammeter EA2258M-10,kiloampermetr EA2258M-10 to the secondary windings of standard current transformers without fear prevent proper operation.
(6) When measuring the DC resistance of the primary and secondary windings of the intermediate transformer of the capacitive voltage transformer, the connection between the primary winding and the voltage dividing capacitor and the external connection of the secondary winding should be disconnected.
The primary winding to the secondary winding andground should be greater than 1000MΩ, and between the secondary windings and to ground should be greater than 10MΩ.
The transformers have beside the two secondary windings required for the realization of the 12 pulse valve bridges a third winding for feeding electric power in the local 220 kV grid.
It is clear from the above diagrams that the current in the primary central phase is twice that of the other two phases,whereas the current in the secondary windings is identical and exactly the same as the one supplied on the load.
The primary winding couples energy into the secondary windings butthe ratio of energy coupled into each of the secondary windings varies in proportion to the relative displacement of a magnetically permeable target.
The three-phase transformer has three windings on both sides, and there is a problem of how to connect them, for example, a star Y or a triangle Δ. Therefore, for a three-phase transformer, in addition to the different connection methods between the three phases,the primary and secondary windings of each phase can also be interchanged.
That sounds simple enough, and most hi-fi products have several secondary windings on their power transformers, providing different voltages to the various parts of the amplifier, or serving the different sections of, say, a CD or network player to avoid noise passing between those sections.
A separately for each secondary winding;
The secondary winding is connected in series with a portion of the core between the windings. .
The load connection to the secondary winding of a resonant transformer allows a positive feedback by returning some secondary energy back to the primary winding. .
Secondary winding(pins 2 and 5 or 3 and 6) should have approximately 70 to 100 Ω.
In this case, the current in the primary winding of the ignition coil changes,what results in reduction in the voltage in its secondary winding.
The secondary winding terminal provides a high voltage, which produces, because of its high frequency, an exotic aura of the electric discharges.
Switching on the appliance power meter in successive chains of I1604- via current transformers with secondary winding to 5A or 1A and a current transformer with a secondary winding on 5A.
The device consists of diode rectifier of the primary chain, the high-frequency generator(inverter), the ferrite transformer,the diode rectifier connected to the secondary winding of the transformer and target inductance(throttle).
If the DC resistance of the secondary winding exceeds 10Ω, a single-arm bridge measurement should be used;
Connecting the E1600 series circuit device(E160) via current transformers with a secondary winding on the 5A or 1A, or through current transformers with a secondary winding on the 5A.
A high voltage pulse in the primary winding produces an increase in magnetic flux andan induction voltage in the secondary winding, which charges the capacitor plates.
As a result of the electrostatic attraction, a vortex leaves the primary winding, rises along the secondary winding, gives an energy to it, and then decays.