Примеры использования To withstand a pressure на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
The gas-tight housing shall be designed to withstand a pressure of 50 kPa. 6.15.13.
Prior to the start-up, the pipeline will be filled with water andwill have to withstand a pressure test.
Class 0: The CNG filter shall be so designed to withstand a pressure of 1.5 times the working pressure MPa.
The materials constituting a device which are in contact with the heat exchange medium of a device when operating shall be compatible with that fluid andshall be designed to withstand a pressure of 200 kPa of the heat exchange medium.
The non-return valve shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) without leakage and deformation.
A-3.5 In the case of hydraulic drive units, a separate piping system is not required for the second steering apparatus control unit if the independent operation of the two steeringcontrols is guaranteed and if the piping system is able to withstand a pressure at least 1.5 times that of the maximum working pressure. .
The LNG heat exchanger- vaporizer shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) without leakage and deformation.
The excess flow valve, if it is not integrated in the cylinder,shall be so designed as to withstand a pressure of 1.5 times the working pressure MPa.
The LNG check valve shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) without leakage and deformation at cryogenic temperature.
The excess flow valve, if it is not integrated in the tank,shall be so designed as to withstand a pressure of 1.5 times the working pressure MPa.
The LNG automatic valve shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) without leakage or deformation see Annex 5A.
Class 1 and Class 2:The CNG filter shall be so designed to withstand a pressure twice the working pressure. .
Class 3: the CNG filter shall be so designed to withstand a pressure twice the relief pressure of the pressure relief valve on which it is subject.
The pressure relief valve and pressure relief device in Class 0 shall be so designed as to withstand a pressure of 1.5 times the working pressure MPa.
The LNG pressure relief valve in Class 5 shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) at cryogenic temperature with the outlet closed off.
The manual valve device in Class 0 shall be designed to withstand a pressure of 1.5 times the working pressure. .
The manual valve device in Class 0 shall be designed to withstand a pressure of 1.5 times the working pressure. .
The manual valve device in Class 0 shall be designed to withstand a pressure of 1.5 times the working pressure. .
The LNG manual valve device in Class 5 shall be designed to withstand a pressure of 1.5 times the working pressure at cryogenic temperature.
The LNG excess flow valve, if it is not mounted inside the tank,shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) at cryogenic temperature.
Each stop-valve orother means of closure shall be designed and constructed to withstand a pressure equal to or greater than 1.5 times the test pressure of the MEGC.
The pressure relief valve and pressure relief device in Class 0 shall be so designed as to withstand a pressure of 1.5 times the working pressure(MPa) with the outlet closed off.
The Class 0 part of the pressure regulator shall withstand a pressure up to 1.5 times the working pressure MPa.
In a tank vessel:a bulkhead constructed to withstand a water pressure of 1.00 metre above the deck;
Capacitors containing dangerous goods shall be designed to withstand a 95 kPa pressure differential;
The hose shall be so designed as to withstand a maximum operating pressure of WP.
The hose shall be so designed as to withstand a maximum operating pressure of 3,000 kPa.
The hose shall be so designed as to withstand a maximum working pressure of 3 MPa.
The standard mechanical load test determines the ability of the module to withstand a wind pressure of 130 km per hour.
The hose shall be so designed as to withstand a maximum working pressure of 1.5 times the working pressure MPa.