Examples of using PCT loops in English and their translations into Russian
{-}
-
Official
-
Colloquial
PCT loops have the following additional properties.
The containers themselves can also contain PCT loops and planning objects in their structure.
To edit PCT loops, you require a license for"EPLANPreplanning P&ID.
Special Topics EPLAN PPE 40 Updating EPLAN PPE Macros 40 Improved Macros for Designing PCT Loops 40.
At PCT loops, macros can be stored, but not parts or function templates.
Accordingly, these options are also displayed in thePI symbol tab for PCT loops and PCT loop functions.
When sorting PCT loops into the existing PCT loop structure, you now have the option of automatic PCT loop numbering.
In this way,for example, you can create action lines between different PCT loops according to the ANSI/ISA-5.1-2009 standard.
Whether you can create and edit PCT loops or planning objects depends on your respective pre-planning license extension.
In parallel to this, this license allows for the graphical placement of PCT loops and PCT loop functions in P&I diagrams.
Influencing Distance While Drawing PCT Loops In this group box you determine the distance of themacros when drawing PCT loops.
Instead of planning objects, with the"EPLANPreplanning P&ID" license you create and edit PCT loops and PCT loop functions.
The PCT loops displayed in this dialog are now- like in the functional view navigator- sorted according to their measurand, processing function, and number.
Preplanning now uses links to enable the definition ofdependencies between different segments, such as PCT loops and PCT loop functions.
Please note that the numbering behavior of PCT loops is affected by the settings under Options> Settings> Projects>"Project name">PPE> PCT loops.
New features in the property dialogs 17 Containers as a New Segment of Pre-Planning 19 Extended Numbering Settings for PCT Loops and Segments 20.
Whether EPLAN PPE accepts for the above actions identical PCT loops project-wide or in relation to the plant depends on the settings in the Identical PCT loop numbers group box.
This namespace contains corresponding classes for the variouspre-planning segments structure segments, planning objects, PCT loops, etc.
On the basis of these settings EPLAN automatically suggests a designation/ PCT loop number when creating segments/ PCT loops, when copying and pasting or when insertingmacros with these objects.
Use this dialog, for example, to specify the properties that are to be identifying besides the"Number" andthe plant levels that allow for identical PCT loops.
Improved graphical working method Toachieve better support for the graphical workingmethod, it is now possible to delete completely the PCT loops and loop functions placed on a project page bymeans of the graphical editor.
Create and Place PCT Loops and PCT Loop Functions If you have the"EPLANPreplanning P&ID" license extension, you can use the pre-planning navigator to create PCT loops and PCT loop functions via theNew planning object popupmenu item.
Sort in connection with the selection of PCT loops When pasting macros or schematic areas with PCT loops, in the Adjust PCT loop structure dialog click a cell of the Number column, followed by the[] button; then, the Select PCT loop dialog opens.
PCT loop element- Device type- Device group.
For example"Structure segment","Planning object","PCT loop", etc.
The PCT loop number is compiled automatically from the properties Technical facility, Measurand, Processing function, andNumber in the PCT loop number group box.
In the PCT loop numbering group box, you can set the start value and increment for the numbering.
A container can be inserted in pre-planning below a structure segment, butnot below a planning object or a PCT loop.
If you selectthe Automatic menu item, the highest available PCT loop number relative to the PI code will be calculated, and the next higher number/ next higher numbers is/ are suggested for the Number column.
If one or several functions or function templates are assigned(in the Functions tab) to a plant, PCT loop, PCT loop function, or PCT loop element(without specification), executing the Draw PCT loop popup menu item(in the Pages tab) will now automatically apply the existing or already-assigned device tags of the functions at the PCT loop to the appropriate functions in the macro assigned.