Examples of using Current loop in English and their translations into Russian
{-}
-
Official
-
Colloquial
Design receiver of current loop 0-20 mA.
The current loop follows the current process.
OFF Error indication via the current loop is deactivated.
Model E6611 current loop indicator is designed for measurement and display of data from various transmitters with standard 4-20 mA analog output.
On potential well of magnetic interaction of ideal current loops.
NORMAL OP The value of the current loop follows the current process.
Selector evaluated despite of the result of next evaluation on the current loop iteration.
During the test, the value of the current loop does not follow the current process.
Indicators that are mapped to the Failure category will normally result in a current loop alarm output.
ALARM LOW Error indication via the current loop is activated failure signal"low" acc. to NE43.
The modular concept allows the use of various types of communication interfaces(e.g. current loop, RS232, RS422, RS485, etc.).
Thecurrent loop is tested byclamp current transformer, sothe operatorcan easily make quick, safe andreliable test without opening the current loop.
¡ôStandard scoreboard interface with 20mA current loop and RS232C two transmission methods.
Current looping kit K54 neutral wire between the clamp and each clamp base is(10,5,± 0,2) mA current programming voltmeter and wattmeter.
If there are two ormore points at the same time, the current loop will be formed between the core and the earth.
This is to ensure that current loop alarms are asserted in situations where the device is not able to provide measurements due to critical failures.(For example, if the alarm selection has not been set to Hold or a fixed current mode is in effect.) A default mapping of all diagnostic indicators will be applied initially.
Each measuring device provides its"main" measured value on the current loop of the standard signal.
The output variables(value of the current loop and indicated flow value) follow the current process by the value set here(in seconds) with a time delay.
Selection/ Input Explanation 2.1 4-20mA OUTP Testing the current loop by setting various current values.
Check whether the sampling or meter display is correct andthe phase sequence of the secondary current loop is correct at the device where each CT secondary winding passes.. According to the requirements of the relay protection commissioning regulations, check whether the grounding point of the CT secondary circuit is correct, and whether there is a phenomenon that the same winding is grounded at two points.
Through the use of generously ratedsurge limiting resistors and a fast acting current loop, all units are fully arc and short circuit protected.
The significance of measuring the DC resistance is to investigate the winding insulation and current loop connection conditions, and can reflect the winding quality of the winding, the winding turn-to-turn short circuit, the winding strand break or the lead wire break, and the tap Faults such as poor switch and wire contact, in fact, it is also an effective means to judge whether the DC resistance of each phase winding is balanced and whether the voltage regulation switch is correct.
In this case the orbiting nucleus functions as an effective current loop, which in turn will generate a magnetic field.
When the HART multi-drop mode(Address 1…15) is activated, the current loop is inactive(fixed current value of"4.5mA") and no longer follows the current process.
The 1000V insulation shaker is used for the external circuit of the inspection object(including the control circuit, signal circuit,AC voltage and current loop), and the 500V insulation shaker is used for the internal circuit of the inspection device.
The Antonia Graza's caught here in this strong current loop and slowly she's been pushed towards those rocks.
The high level sensor referred to in 9.3.1.21.1(d) shall give a visual and audible alarm on board andat the same time actuate an electrical contact which in the form of a binary signal interrupts the electric current loop provided and fed by the shore facility, thus initiating measures at the shore facility against overflowing during loading operations.
Connecting power to electronic decentralized(distributed)is a seemingly trivial matter, because of the current loops, noise and other nuances in transient states may disrupt, even professionals involved in electronics, electrical and automation.
Tripping coils I andII are two completely independent trip current loops, and the two loops function exactly the same.
Backup heater thermal protector Q1L b Transformer TR1 c Backup heater contactors K1M d Backup heater circuit breaker F1B e Connectors X6YA/X6YB/X6Y f Current loop PCB A6P g Terminal block X2M(high voltage) h Terminal block X1M(to outdoor unit) i 3-way valve relay K2M and K3M j Extension PCB A5P k.