No transitional measures would be needed,as 1.6.3.31 already covers the continued use of tank vehicles and demountable tanks constructed in accordance with standards applicable at the time of their construction.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 January 2003 in accordance with the requirements of 6.8.2.1.21 in force up to 31 December 2002 but which do not, however, conform to the requirements applicable as from 1 January 2003 may still be used.
For UN No. 2381, the tank code specified in column(12)of Table A of Chapter 3.2 applicable up to 31 December 2012 may continue to be applied until 31 December 2018 for fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2013.
Vacuum-operated waste fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2005 in accordance with the requirements applicable up to 31 December 2004 but which do not conform to the requirements of 6.10.3.9 applicable as from 1 January 2005, may still be used.
Tank-vehicles and demountable tanks constructed before 1 July 2013 in accordance with the requirements in force up to 31 December 2012, but which do not, however, meet the marking provisions of 6.8.2.5.2 or 6.8.3.5.6 applicable as from 1 January 2013, may continue to be marked in accordance with the requirements applicable up to 31 December 2012 until the next periodic inspection after 1 July 2013.
RID: Tank-wagons/ADR: Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2007 in accordance with the requirements in force up to 31 December 2006 and which do not, however, conform to the requirements of 6.8.2.2.3 applicable as from 1 January 2007 may continue to be used until the next periodic inspection.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2007 in accordance with the requirements in force up to 31 December 2006 but which do not, however, conform to the requirements of 6.8.2.2.3 applicable as from 1 January 2007 may continue to be used until the next periodic inspection.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2003 in accordance with the requirements in force up to 31 December 2002 but which do not, however, conform to the requirements of 6.8.2.1.7 and special provision TE15 of 6.8.4(b) applicable as from 1 January 2003 may still be used.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 January 2012 in accordance with the requirements in force up to 31 December 2012, but which do not however conform to the requirements of 6.8.2.6 relating to standards EN 14432:2006 and EN 14433:2006 applicable as from 1 January 2011, may still be used.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2011 in accordance with the requirements of 6.8.2.2.3 in force up to 31 December 2010 but which do not, however, conform to the requirements of 6.8.2.2.3, third paragraph, concerning the position of the flame trap or flame arrester may still be used.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 January 2007 in accordance with the requirements in force up to 31 December 2006 but which do not, however, conform to the requirements applicable as from 1 January 2007 regarding the marking of the external design pressure in accordance with 6.8.2.5.1, may still be used.
X Fixed tanks(tank vehicles) and demountable tanks constructed before 1 January 2007 in accordance with the requirements of 6.8.2.6 in relation to the properties of the material for manhole cover assemblies applicable up to 31 December 2006 but which do not, however, conform to these requirements of 6.8.2.6 applicable from 1 January 2007 may continue to be used until the next periodic inspection.
Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 January 2003 in accordance with the requirements applicable up to 30 June 2001, which conform to the requirements of 6.8.2.2.10 but are not equipped with a pressure gauge or another suitable indicator, shall nevertheless be considered as being hermetically closed until the next periodic inspection according to 6.8.2.4.2 but not later than 31 December 2008.
X Fixed tanks(tank-vehicles) and demountable tanks constructed before 1 July 2007 in accordance with the requirements in force up to 31 December 2006, but which do not comply with the requirements of 6.8.2.5.1, with respect to the indication of the design vacuum pressure, shall be provided with the inscription"vacuum valves" on the tank plate or on the shell itself, if the application of vacuum valves is deemed necessary by the competent authority, at the next periodical inspection according to 6.8.2.4.2 and not later than 30 June 2013.
X} Fixed tanks and demountable tanks/vacuum-operated waste tank-containers constructed before 1 January 2005, conform to the requirements of 6.1.10.3.9 applicable as from 1 January 2003, may still be used.
Requirements for tank-vehicles, demountable tanks and tank- containers which are designed, constructed and tested according to standards.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed after 1 October 1978, in accordance with the provisions of ADR in force at the date of their construction, may continue to be used.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed before the entry into force or the provisions applicable from 1 January… which do not conform to those provisions but were constructed according to the requirements of ADR in force until that date may still be used.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed before the entry into force of the requirements applicable from 1 January 1999 which do not conform to those requirements but were constructed according to the requirements of ADR in force until that date may still be used.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed between 1 January 1978 and 31 December 1984, if used after 31 December 2004, shall conform to the requirements of[marginal 211 127(5)], applicable as from 1 January 1990, concerning wall thickness and protection against damage.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed before 1 May 1985 in accordance with the requirements of ADR in force between 1 October 1978 and 30 April 1985 but not conforming to the requirements applicable from 1 May 1985 may continue to be used after that date.
Fixed tanks(tank vehicles), demountable tanks and battery vehicles constructed before the entry into force of the provisions applicable from[1 January 2001] which do not conform to those provisions but were constructed according to the requirements of ADR in force until that date may still be used.
ADR(a) Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed before 1 May 1985 in accordance with the requirements of ADR in force between 1 October 1978 and 30 April 1985 but not conforming to the requirements applicable as from 1 May 1985[text of amendments] may continue to be used after that date.
Fixed tanks(tank vehicles), demountable tanks and batteries of receptacles constructed between 1 January 1978 and 31 December 1984, if used after 31 December 2004, shall conform to the provisions of marginal 211 127(5), applicable as from 1 January 1990, concerning wall thickness and protection against damage.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed between 1 May 1985 and the entry into force of the requirements applicable as from 1 January 1988[text of amendments] which do not conform to those requirements but were constructed according to the requirements of ADR in force until that date may continue to be use.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed before 1 October 1978 which have been used in accordance with the provisions of the transitional measures in force in ADR between 1 October 1978 and 1 January 2001, but which do not conform to the provisions of this Appendix, may continue to be used until 31 December 2004.
Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed between 1 January 1985 and 31 December 1989 before 1 January 1990, if used after 31 December 2010, shall conform to the requirements of marginal 211 127(5), applicable as from 1 January 1990, may still be used provided they conform to the requirements of 6.8.2.1.20 concerning shell thickness and protection against damage.
XX Fixed tanks(tank vehicles) and demountable tanks non-vacuum insulated constructed and approved for the carriage of LNG before 30 September 2013 in accordance with the requirements in force up to 31 December 2014, but which do not conform to the requirements of 6.8.2.6 relating to standard EN 14.398-2:2003(except table 1) applicable as from 1 January 2009, may continue to be used for the transport of LNG only.
For fixed tanks(tank-vehicles), demountable tanks and battery-vehicles constructed before 1 January 2007 which do not conform to the requirements of 4.3.2, 6.8.2.4 and 6.8.3.4 concerning the tank record, the retention of files for the tank record shall start at the latest at the next periodic inspection.
For[RID: Tank-wagons/ADR: Fixed tanks(tank-vehicles), demountable tanks and battery-vehicles] constructed before 1 January 2007 which do not comply with the requirements of 4.3.2, 6.8.2.4 and 6.8.3.4 concerning the tank record, the retention of files for the tank record shall start at the latest at the next periodic inspection.