Examples of using Dew point in English and their translations into Czech
{-}
-
Colloquial
-
Official
Read heat index and dew point.
Dew point measurement Pressure monitoring.
Wind, temperature, Coriolis? dew point.
Pressure dew point quality class according to ISO 8573-11-6.
Scan to watch the video clip explaining dew point measurement.
Outdoor dew point in degree C or F refer SETUP mode for temperature unit setting.
Achieves required pressure dew point with minimum energy input.
Optimised refrigeration compressor technology for low energy consumption and stable pressure dew point.
The conventional control procedures are dew point control or enthalpy control.
Dew point temperature is a temperature at which air reaches the state of saturation and water starts to precipitate.
Temperature, humidity, barometric pressure and dew point temperature sensors.
The ambient dew point will equal also to 0 C, but the pressure dew point at 7barA will be over 30 C!
Reading next to this symbol is calculated dew point temperature or error state of value.
The dew point is the saturation point of the air, or the temperature to which the air has to be cooled in order to get condensation.
This method of dehumidification is based on condensation of water vapor contained in the air during air cooling below dew point.
The ambient air is cooled to below the dew point and the water vapour contained in the air condenses as condensate or frost on the evaporator fins.
The unit therefore automatically switches over tothe heat-regenerated adsorption dryer, so that a pressure dew point of below -40 C is achieved.
Press the HEAT INDEX/ DEW POINT button twice to show the respective indoor or outdoor dew point reading on the display.
Nominal cooling capacity is stated for air temperature of 35 C in hot zone, without condensation relative humidity under dew point.
The dew point is a temperature where the air at constant barometric pressure no longer holds its water vapours and some of the moisture condensate to liquid water.
As a protection against post-condensation and freeze-ups in winter for example, a pressure dew point of better than minus 40 C must be provided.
Channel number of remote sensor- channel 1, 2 or 3- Dew point is the temperature to which the air has to be cooled in order to get condensation- Heat Index combines the effects of heat and humidity.
The presence of cold zones in the generator orflue gas chimney can lower the temperature of the flue gas down to the dew point, causing condensation to occur.
A constant low pressure dew point combined with a droplet separation rate of close to 99 percent, minimum maintenance and low operating costs are other strong points of the DRYPOINT RA.
Press“MEMORY” repeatedly to view the maximum and minimum values of temperature, humidity,heat index, dew point, and wind speed and wind chill readings.
In this operating mode, the pressure dew point at the outlet is set to a value between +10 and -26 C, and the DRYPOINT M eco control keeps this value constant, even under changing operating conditions.
This extremely low pressure drop, combined with maximum efficiency,makes the DRYPOINT RA cost-efficient and also keeps the pressure dew point constant.
Value LED of lower value next to the setting flashes: Value 45 K/ -15 C(example)If the achieved pressure dew point once again complies with the set point value, then the normal operating mode will commence again.
Munters desiccant dehumidification systems operate below 10 C,preventing condensation occurring by removing moisture from the air and creating a dew point below 4 C.
This communication protocol supports read temperature at C, relative humidity,one of computed value(dew point temperature or absolute humidity) and barometric pressure at kPa depended by device type.