Примеры использования Maximum expected на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
The planned number represented the maximum expected number of meetings.
The maximum expected CO2 concentration during emission testing, xCO2exp shall be estimated.
The chiller shall allow for measuring at least 95 per cent of the total NO2 at the maximum expected concentration of NO2.
The maximum expected mole fraction of water during emission testing, xH2Oexp shall be estimated.
Does the Company have scenarios for the minimum and maximum expected tariff growth rates in 2017?
XCO2exp maximum expected concentration of CO2 during emission testing, according to paragraph 8.1.11.2.2.
A CO2 span gas concentration shall be used at least as high as the maximum expected during testing.
Maximum expected level at the end of the year might reach an average of 1.62, and it is 2.6% below the current level.
Additionally, make sure the unit is positioned at least 100 mm above the maximum expected level of snow.
XH2Oexp maximum expected mole fraction of water during emission testing according to paragraph 8.1.11.2.1.
The sample dryer shall allow for measuring at least 95 per cent of the total NO2 at the maximum expected concentration of NO2.
The targeted specifications, including mass,volume, maximum expected operating pressure, propellant expulsion efficiency and propellant storage life.
An NO2-to-NO converter shall allow for measuring at least 95 per cent of the total NO2 at the maximum expected concentration of NO2.
The capacity value is to be calculated so that at maximum expected throughput signal faces remain steep enough not to cause transmission errors.
Ii NO2 calibration gas(balance gas of dry air)that has an NO2 concentration that is near the maximum expected during testing shall be selected.
When estimating the maximum expected CO2 concentration, the maximum expected CO2 content in fuel combustion products and dilution air shall be considered.
If the sample is not passed through a dryer, control the vessel temperature to generate an H2O level at least as high as the maximum expected during testing.
This risk is expressed in a credit equivalent,which can be taken as the maximum expected replacement cost of the contract with a 90 to 99 per cent certitude, in statistical terms.
If the sample is not passed through a dryer, the vessel temperature shall be controlled to generate an H2O level at least as high as the maximum expected during testing.
The temperature shall be increased in reasonable steps until the maximum expected diluted exhaust temperature expected during the emissions test is reached.
When estimating the maximum expected mole fraction of water, the maximum expected water content in combustion air, fuel combustion products, and dilution air(if applicable) shall be considered.
Therefore, the simulated results represent a safe bound of the damage,defining the conditions for the maximum expected damage area from any surface-initiated spall.
Every empty aerosol dispenser shall be subjected to a pressure equal to or in excess of the maximum expected in the filled aerosol dispensers at 55 °C 50 °C if the liquid phase does not exceed 95% of the capacity of the receptacle at 50 °C.
If the CO2 and H2O levels used are higher than the maximum levels expected during testing,each observed interference value shall be scaled down by multiplying the observed interference by the ratio of the maximum expected concentration value to the actual value used during this procedure.
Each gas cartridge orfuel cell cartridge shall be subjected to a test pressure equal to or in excess of the maximum expected in the filled receptacle at 55 °C 50 °C if the liquid phase does not exceed 95% of the capacity of the receptacle at 50 °C.
Separate interference procedures concentrations of H2O(down to 0.025 mol/mol H2O content) that are lower than the maximum levels expected during testing may be run, butthe observed H2O interference shall be scaled up by multiplying the observed interference by the ratio of the maximum expected H2O concentration value to the actual value used during this procedure.
If the humidified NO span gas is introduced into the sample system upstream of a sample dryer during the verification test,it is not needed to estimate the maximum expected mole fraction of water and xH2Oexp shall be set equal to xH2Omeas.
If the CO2 and H2O levels used are higher than the maximum levels expected during testing,each observed interference value shall be scaled down by multiplying the observed interference by the ratio of the maximum expected concentration value to the actual value used during this procedure.
Separate interference procedures concentrations of H2O that are lower than the maximum levels expected during testing may be run, butthe observed H2O interference shall be scaled up by multiplying the observed interference by the ratio of the maximum expected H2O concentration value to the actual value used during this procedure.
Separate interference procedures concentrations of H2O that are lower than the maximum levels expected during testing may be run, butthe observed H2O interference shall be scaled up by multiplying the observed interference by the ratio of the maximum expected H2O concentration value to the actual value used during this procedure.