Примеры использования Pressure-relief device на Английском языке и их переводы на Русский язык
{-}
-
Official
-
Colloquial
Marking of pressure-relief devices.
All portable tanks shall be fitted with at least one pressure-relief device.
Pressure-relief devices shall be approved by the competent authority or its authorized body.
Insert"spring-loaded" before"pressure-relief devices.
Every pressure-relief device shall be plainly and permanently marked with the following.
Insert the words"spring-loaded" before"pressure-relief devices.
Emergency pressure-relief devices may be of the spring-loaded, frangible or fusible type.
X536(1) Shells shall be fitted with safety valves and pressure-relief devices.
The pressure-relief device shall be of the type that will resist dynamic forces including surge.
Closed cryogenic receptacles shall be fitted with at least one pressure-relief device.
The inlet to the pressure-relief device shall be sited in the vapour space of the IBC under maximum filling conditions during transport.
X536(1) Tanks shall be fitted with safety valves and emergency pressure-relief devices.
Pressure-relief devices of portable tanks used for the transport of Class 8 substances shall be inspected at intervals not exceeding one year.
T absolute temperature in Kelvin(°C+ 273) above the pressure-relief devices in the accumulating condition;
Each pressure-relief device inlet shall be situated on top of the shell in a position as near the longitudinal and transverse centre of the shell as reasonably practicable.
Page 45 6.7.4.10.1 Amend the beginning to read as follows:"Each pressure-relief device inlet shall be.
The pressure-relief devices shall open automatically at a pressure not less than the MAWP and be fully open at a pressure equal to 110% of the MAWP.
Check of service equipment,other accessories and pressure-relief devices, if to be reintroduced into service.
When no spring-loaded pressure-relief device is used, the frangible disc shall be set to rupture at a nominal pressure equal to the test pressure.
However, it was not necessarily appropriately worded,since it implied that a pressure-relief device was always required, which was not the case in RID or ADR.
Pressure-relief devices shall be designed to prevent the entry of foreign matter, the leakage of gas and the development of any dangerous excess pressure.
There shall be no obstruction in an opening leading to a vent or pressure-relief device which might restrict or cut-off the flow from the shell to that device. .
Portable tanks intended for the transport of certain non-refrigerated liquefied gases identified in portable tank instruction T50 in 4.2.4.2.6 shall have a pressure-relief device approved by the competent authority.
Every portable tank with a capacity less than 1,900 litres shall be fitted with a pressure-relief device which may be a frangible disc when this disc complies with the requirements of 6.6.2.11.1.
All pressure-relief device inlets shall under maximum filling conditions be situated in the vapour space of the shell and the devices shall be so arranged as to ensure the escaping vapour is discharged unrestrictedly.
There shall be no obstruction in an opening leading to or leaving from a vent or pressure-relief device which might restrict or cut-off the flow from the element to that device. .
When required for certain substances by the applicable portable tank instruction identified in Column 10 of the Dangerous Goods List and described in 4.2.4.2.6,portable tanks shall have a pressure-relief device approved by the competent authority.
Other openings, except for openings leading to venting or pressure-relief devices, shall be equipped with either a stop-valve or another suitable means of closure located as close to the shell as reasonably practicable.
MEGCs used for the transport of certain non-refrigerated gases identified in instruction T50 in 4.2.5.2.6 may have a pressure-relief device as required by the competent authority of the country of use.
All pressure-relief device inlets shall under maximum filling conditions be situated in the vapour space of the closed cryogenic receptacle and the devices shall be so arranged as to ensure that the escaping vapour is discharged unrestrictedly.