Mount the test fixture.
A test fixture to mount the doors.
Each shall be attached rigidly to the test fixture.
A typical static test fixture is illustrated in Figure 3-1.
Pneumatic Side Acting Grips or relevant test fixture.
Attach the test fixture to the mounting provisions of the latch and striker.
Attach the hinge system to the mounting provision of the test fixture.
Adapt the test fixture to the mounting provisions of the latch and striker.
Mount the latch and striker in the fully latched position to the test fixture.
The test fixture shall be rigidly secured to prevent movement during impact.
Mount the door assemblies either separately or combined to the test fixture.
The tested-device shall be connected to the test fixture as recommended by the manufacturer.
Test fixture: One set of tensile plates to meet the standard for testing specimens.
We suggest reviewing ISO 1798 to fully understand the test fixture and results requirements.
Test fixture: One set of compression anvils to meet the standard for testing specimens up to 300mm x 300mm.
The demonstration may be performanced wither in the vehicle orwith the door retention components in a bench test fixture.
The valve unit are installed in a test fixture corresponding to the manufacturer's specifications for installation.
On request of the manufacturer andwith the agreement of the technical service the tank may be tested without using any test fixture.
Mount the test fixture in the fully latched position to the test fixture in the test machine.
We recommend reviewing the ISO 14130 in full to understand the test fixture and results requirements relevant to the materials you are testing. .
The test fixture accurately replicates bending movement during a single cycle test, as well as fatigue evaluation of the plate material and design.
During the off cycle the downstream pressure of the test fixture shall be allowed to decay to 50 per cent of the MAWP of the component.
Attach a test fixture to the mounting provision of the hinge system, simulating vehicle position(door fully closed) relative to the hinge centerline.
The DX or HDX Model dual test space load frames allow the bend test fixture to be positioned in the lower compression test. .
A check valve is connected to a test fixture and pressure 100 per cent NWP(+2/-0MPa) is applied in six step pulses to the check valve inlet with the outlet closed.
The test sample tested in accordance with paragraph 1. shall be subjected to the test described in paragraph 2.1., without being removed from or readjusted in relation to its test fixture.
A check valve is connected to a test fixture and pressure is applied in six pulses to the check valve inlet with the outlet closed.
The test fixture shall be constructed such that there is no contact with any part of the leg assembly, other than at the fixing point, during the test. .
The tank and all its accessories must be mounted onto a test fixture in a manner corresponding to the mode of installation on the vehicle for which the tank is intended.
A sample device mounted on a test fixture, with initial CIL measured and recorded shall be subjected to a water spray as follows.