The TPMS shall be calibrated and tested.
Each normally used operating range shall be calibrated.
It shall be calibrated on a carbon number basis of one C1.
A CFV flow meter shall be calibrated as follows.
The NDIR shall be calibrated either with water vapour or with propylene C3H6.
A CVS system that has multiple speeds shall be calibrated on each speed used.
Ii Each CFV shall be calibrated according to this paragraph and Annexes A.7A.8.
The performance of the device used to actuate the brake shall be calibrated within an accuracy of 1 per cent.
The CVS system shall be calibrated by using an accurate flowmeter and a restricting device.
The equipment used for setting andcontrolling the current and voltage shall be calibrated to the national standard.
The gas divider shall be calibrated by the instrument manufacturer.
The total system shall meet the accuracy specifications for the exhaust gas flow and shall be calibrated according to Appendix 2, paragraph 1.11.2.
The CVS system shall be calibrated by using an accurate flowmeter and a restricting device.
An SSV flow-meter shall be calibrated as follows.
All instruments shall be calibrated including laboratory vessels, pipets and etc., it is important to make sure that FT-IR microscope is working properly and for this purpose it is recommended to procure liquid nitrogen and Dewar container.
For all FID analyzers, the FID shall be calibrated upon initial installation.
The PDP shall be calibrated by using the collected data and the equations in Annexes A.7-A.8;
To eliminate the weight of the empty pallet from the crowd,pallet scales shall be calibrated and in any subsequent weighing pallet weight is automatically excluded.
The analysers shall be calibrated like the analysers for the measurement of the gaseous emissions.
A CFV flow-meter shall be calibrated as follows.
Instruments shall be calibrated for measuring pressure, temperature, and dew point upon initial installation.
A PDP flow meter shall be calibrated as follows.
A data channel shall be calibrated at least once a year against reference equipment traceable to known standards.
A PDP flow-meter shall be calibrated as follows.
The test machine shall be calibrated for speed and brake torque within an accuracy of 2 per cent taking into account the internal friction characteristics.
The analyser(if required) shall be calibrated, then zeroed and spanned.
The CVS system shall be calibrated by using an accurate flow-meter and a restricting device.
The analyser(if required) shall be calibrated, then zeroed and spanned.
The test machine shall be calibrated for speed and brake output torque within an accuracy of 2 per cent.
The torque measuring system shall be calibrated to take friction losses into account.